COSHH Essentials: What It Covers and Misses
What COSHH Essentials Is
COSHH Essentials is HSE's free control-banding scheme. In HSE's own words, it "sets out basic advice on what to do to control exposure to hazardous substances in the workplace", and "takes the form of straightforward advice in 'factsheets' called 'control guidance sheets'."
What it gives you is a recommended level of control for a task, arrived at without measuring anything. You classify the substance into a hazard group from its H-statements, estimate how much of it gets into the air from the quantity and volatility involved, and the scheme returns one of four control approaches with a sheet describing what that looks like in practice.
That is genuinely valuable for a small business with no occupational hygienist, and it is free. It is also bounded in three specific ways that are stated plainly in HSE's own technical documentation and almost nowhere else — it cannot deal with gases, it cannot deal with liquids used above their boiling point, and for carcinogens, mutagens and respiratory sensitisers it tells you to get specialist advice rather than giving you an answer.
Knowing those three boundaries is the difference between using the scheme well and assuming it has covered you.
The Four Control Approaches
The scheme's output is one of four approaches, set out in HSE's technical basis document:
| Approach | Type | Relative efficacy | What it means |
|---|---|---|---|
| 1 | General ventilation | baseline | "A good standard of general ventilation and good working practices" |
| 2 | Engineering control | 10-fold reduction | Local exhaust ventilation, from capturing and receiving hoods to partial enclosure |
| 3 | Containment | 100-fold reduction | "Full enclosures and containment, where small-scale breaches may be expected" |
| 4 | Special | — | "Expert advice is required" |
There is also a Control approach S, which sits alongside rather than within the numbered ladder. It applies where a substance is a concern on direct contact — irritation, corrosivity, sensitisation, or absorption through the skin — and focuses on preventing skin and eye contact rather than airborne exposure.
Approach 4 is worth reading carefully. It is not a higher grade of engineering control you can buy. It is the scheme saying this one is outside what a generic method can decide.
Approaches 1 to 3 map neatly onto the middle of the COSHH hierarchy of control — which is why the scheme's output slots into an assessment rather than replacing one.
How the Banding Works
Three inputs, and understanding them tells you where the answer comes from.
Hazard group, from the label. Substances are allocated to hazard groups A to E based on their H-statements under CLP — the same classification that appears on the container. Groups A to D correspond to airborne concentration ranges that the scheme treats as adequate control. The upper boundary, the top of Group A, is "500 parts per million (ppm) for vapours and 10 milligrams per cubic metre (mg/m3) for dusts". If you are not confident reading H-statements off a label, our guide to COSHH hazard symbols and how to read a safety data sheet cover where they come from.
Exposure potential, from quantity and volatility. How much you use, and how readily it gets into the air — dustiness for solids, boiling point or vapour pressure for liquids.
Duration, as a coarse filter. The scheme carries "a threshold of 15 minutes' use per day", below which the recommended approach drops one step — containment to engineering control, or engineering control to general ventilation. A useful thing to know if your task genuinely is brief, and a dangerous thing to assume if it is not.
Two honest caveats HSE states about the method itself. The generic risk assessment scheme is explicitly "not intended for use as an exposure model" — it recommends a level of control, it does not predict your actual exposure. And the technical basis document is "aimed at occupational hygienists and others"; the control guidance sheets are the part written for employers.
The Three Boundaries
1. It cannot deal with gases
The scheme's cut-offs are a boiling point of 20°C and a vapour pressure of one atmosphere. HSE's technical basis states the consequence directly:
"Such substances will be in the vapour phase at room temperature (a gas), and COSHH essentials cannot deal with gases."
The same document puts it more broadly at the front: "the generic risk assessment applies to liquids and solids only; it does not apply to gases or to liquids used above their boiling point."
If you use compressed or liquefied gases — welding shielding gas, LPG, refrigerants, medical gases, CO₂ for dispensing — COSHH Essentials is not the tool for those. They still need assessing; they need assessing another way.
2. It cannot deal with liquids used above their boiling point
A solvent assessed cold and a solvent used in a heated process are different exposure problems, and the scheme's inputs assume the former. Hot processes — heated dip tanks, hot-melt adhesives, anything where a liquid is worked near or above its boiling point — sit outside the method.
3. It does not answer for Hazard Group E
This is the most important boundary and the easiest to miss, because Group E substances are common.
"For some toxicological effects – genetic damage and cancer arising from it, and respiratory sensitisation – the available data and our current state of knowledge do not allow confident identification of exposure levels that present no significant risk. The H-statements relating to these hazardous properties have been assigned to Hazard Group E. For these substances, specialist advice should be sought and implemented on a case-by-case basis."
Membership of Group E is decided mechanically, by CLP hazard statement rather than by reputation. Table 1 of the technical basis allocates five to it: H334 ("may cause allergy or asthma symptoms or breathing difficulties if inhaled"), H340 ("may cause genetic defects"), H341 ("suspected of causing genetic defects"), H350 ("may cause cancer") and EUH070 ("toxic by eye contact") — HSE's table shortens the last of those to "EU70", but the code a supplier actually prints in section 2 of a safety data sheet is the CLP form, EUH070. So the check is a reading task — open section 2 of the safety data sheet and look for those codes. Note what is not on the list: H351, "suspected of causing cancer", sits in Group D, so a suspected carcinogen still bands normally.
The harder cases are the substances that arrive in no container at all, and so carry no supplier H-statement for the banding to read. Hardwood dust, respirable crystalline silica and welding fume are all hazards this site covers in depth, and all three are process-generated: HSE states hardwood dust "can cause cancer, particularly of the nose", that silica "may also be linked to lung cancer", and that IARC "conclude that all welding fume can cause lung cancer and may cause kidney cancer, classifying all welding fume as Group 1 carcinogenic substances". None of them, though, has an SDS to band from. That is precisely why HSE does not leave them to the generic scheme: it publishes dedicated direct advice sheets for woodworking, silica and welding, listed below. Our guides to silica dust, wood dust, welding fume and occupational asthma cover what those duties look like in practice.
COSHH regulation 7 reinforces the point: for carcinogens and mutagens, regulation 7(5) requires additional measures on top of the normal hierarchy, and for asthmagens, regulation 7(7)(c)(ii) requires exposure to be reduced "to as low a level as is reasonably practicable" rather than merely below a limit. A generic banding scheme cannot tell you when you have reached that.
What the Sheets Actually Are
Two families, both free:
Direct advice sheets — industry-specific, covering agriculture, flour, metalworking fluids, microelectronics, motor vehicle repair, offshore, printing, RPE, rubber, service and retail, silica (with sets for brick and tile, ceramics, construction, foundry, manufacturing, quarries and stoneworkers), skin and eye contact, welding, woodworking, and dichloromethane.
Generic control guidance sheets — task-based rather than industry-based, covering common operations such as mixing, filling and weighing.
If your trade is on the direct-advice list, start there: the sheets describe realistic control for your actual tasks. If it is not, the generic sheets are a sound starting point for the operation you are doing.
Where Your Assessment Still Starts
COSHH Essentials helps with one part of the assessment — deciding what level of control is appropriate. It does not do the assessment, and regulation 6(1) is clear about what the assessment is: an employer may not carry out work liable to expose employees to a substance hazardous to health unless they have "made a suitable and sufficient assessment of the risk created by that work to the health of those employees and of the steps that need to be taken to meet the requirements of these Regulations" — and implemented those steps.
So the parts that remain yours:
- The substance inventory. Nothing external knows what is in your building. A current chemical register is the input to everything else.
- Who is exposed, to what, for how long. Task by task, person by person.
- Whether the recommended control is actually in place and working. A sheet recommending LEV is not LEV. Where you fit extraction, it needs testing on schedule.
- Everything the scheme excludes — gases, hot liquids, Group E substances, and any process-generated dust or fume with no SDS for the banding to read.
- Health surveillance, training, monitoring, emergency arrangements. Regulations 10 to 13, none of which control banding touches.
- Review. Regulation 6(3) requires the assessment to be reviewed regularly and forthwith on a significant change — our guide to reviewing a COSHH assessment covers the triggers.
The useful way to hold it: COSHH Essentials is a good answer to "what standard of control should this task have?" and not an answer to "are we compliant?" Used as the first, it saves a small business real money. Used as the second, it leaves out the substances most likely to cause harm.
Our step-by-step guide to doing a COSHH assessment covers the whole process the sheets fit into, and the free COSHH checker is a quick way to see which of your substances need attention first.
Quick Checklist
- Every substance has been checked against the three exclusions — gas, used above boiling point, Hazard Group E
- Group E substances — the ones carrying H334, H340, H341, H350 or EUH070 on the SDS — are being handled on specialist advice, not on a banding output
- Process-generated dusts and fumes with no SDS (wood dust, silica, welding fume) have been taken to the relevant direct advice sheet rather than the generic banding
- Gases are assessed by another route
- The 15-minute duration filter has only been relied on where the task genuinely is that brief
- The recommended control approach is actually installed, used and maintained — not just recommended
- The direct advice sheet for your trade has been read, if one exists
- The assessment covers the things banding does not: exposure monitoring, health surveillance, training, emergencies
- Significant findings are recorded if you employ five or more people
- A review cycle exists
Between the Free Sheets and an Assessment
The gap COSHH Essentials leaves is not advice — HSE's sheets are good. It is the record: which substances you hold, which sheet or decision applies to each, what you actually installed, when it was last looked at, and which ones the scheme explicitly did not answer for.
COSHHmate is being built to be that record — a register where each substance carries its classification and its controls, assessments that hang off it, and review dates that come round on their own. It does not replace HSE's guidance; it keeps track of what you decided after reading it. Pricing will be a flat monthly fee with no per-user charges. If your COSHH Essentials sheets are currently a folder nobody can audit, join the waitlist.
Sources
- HSE — COSHH essentials
- HSE — COSHH essentials: Controlling exposure to chemicals, a simple control banding approach (technical basis)
- HSE G409 — COSHH essentials general guidance: Exposure measurement, air sampling (Control approach 4: Special)
- HSE — Wood dust: hardwood dust and cancer risk
- HSE — Silicosis: causes and risk controls
- COSHH Regulations 2002, regulation 6 — Assessment of health risks
- COSHH Regulations 2002, regulation 7 — Prevention or control of exposure
- CLP Regulation (EC) No 1272/2008, Annex II — supplemental hazard statements, including EUH070
This is general guidance based on HSE's published COSHH Essentials material and the text of the COSHH Regulations 2002, which extend to England, Wales and Scotland; Northern Ireland has its own equivalent provisions enforced by HSENI. Where a substance falls in Hazard Group E, HSE's own position is that specialist advice should be sought on a case-by-case basis — take it. Not legal advice.
Get notified when COSHHmate launches